Resource Center System

Ion exchange resin regeneration

Patrone i

Cylinder type ion exchanger

Patrone i-e

Cartridge type miniaturized ion exchanger

ECONOSELFY

Onsite ion exchange regeneration unit

RO+IER

Pure water unit

S.R.B. Ion exchanger

Counterflow regeneration type

Vacuum evaporator

Optimal for concentration recovery of various solutions

NICKEL BACK

Vaccum evaporator for nickel plating liquid use

Rising Thin Film Vacuum Evaporator

Long tube vertical type vaccum evaporator

KANRY®

Evaporator

KANRY®CLEAN

Closed-loop atmospheric evaporator

Recyter

Acid and metal salt separator

ECONITRY

Nitric acid activating bath control unit

KANRY®Evaporator

KANRY® is a comprehensive management system for plating solutions which integrates the following two mechanisms into a single compact system: a concentrating mechanism that significantly reduces make-up water through concentration recovery of plating solutions; and an electrolysis mechanism that simultaneously recovers metals, adjusts concentrations and removes impurities.

Features

  • Efficiently evaporates and concentrates water in plating solutions, and recovers plating chemicals discharged in the rinse process.
  • Simply structure due to an atmosphere-type evaporation mechanism which uses air, and there is no need to use cooling water or worry about decomposition of the plating solutions.
  • In chromium plating, an attached diaphragm electrolysis unit separates and removes impurities (positive ions) from plating solutions, to prevent impurities from increasing.
  • In nickel plating, an attached electrodeposition unit performs electrodeposition (metalization) or reverse electrolysis according to the concentration of the plating solution, and maintains a designated concentration.
  • Very easy to operate with very few parts to break down, and requiring neither maintenance nor labor.
  • A streamlined overall structural design with sufficient corrosion resistance thanks to the low-temperature evaporative concentration system.
  • The integrated unit saves installation space and costs compared to conventional equipment.

KANRY®

Applications

  • Concentration of plating (Cu, Ni, Cr, Zn plating) process water
  • Volume reduction of wastewater

Technical specifications

Model W1F-50 W1F-100 W1F-200
Evaporation capacity 50 – 60L/h 90 – 120L/h 180 – 220L/h
Dimensions[W×D×H] 1,100×1,000×2,420mm 1,350×1,100×2,600mm 2,570×1,800×3,110mm
Calorie consumption 125.6 – 146.5MJ/h 251.2 – 293.0MJ/h 502.4 – 544.3MJ/h
Heat exchanger heat transfer area 0.5m2 0.75m2 2.0m2
Power consumption 1.5kW 1.5kW 5.5kW
Operating weight 450kg 600kg 900kg

* The heat exchanger and circulation pump are installed separately.

* The evaporation capacity will vary depending on temperature and humidity.

Movie Econoback System