EcoAce®PLUS

Micro-clarifying filter

MMFS

Multi media filtration system

Model F30

for medium-sized plating baths with capacities up to 2000L

Model F40

for large-sized plating baths with capacities up to 4000L

Model F55

for large-sized plating baths with capacities up to 8000L

Model F55A

for alkaline zinc plating baths with capacities up to 8000L

Model SYL

Micro-clarifying filter

REPRESSTOR

Compact PF automatic dewatering fiiter

FK Filter

Automatic dewatering filter

Model FD

Tubular backwash type micro-clarifying filter

Model FDS

Sepaner PTFE membrane filtration system

Filtration system for steel sheet surface treatment

Filter Model FD & Dewatering Filter Model FK/PF

Filtration system for conversion treatment solution

Filter Model FD & Dewatering Filter Model FK/PF

Filtration system for coolant oils

Filter Model FD & Dewatering Filter Model FK/PF

Filtration system for chemical industries

Filter Model FD & Dewatering Filter Model FK/PF

FILTRATA-Oh

Pre-treatment (degreasing) total system

NEKKO

Heat exchanger

Filter media series

Cartridge · Filter cloth · Bag · Others

EconoCross

Membrane filter

Sepaner PTFE membrane filtration systemModel FDS Clarifying Filter

The Sepaner filtration system is an innovative, fully automatic filtration system which can continuously separate/concentrate suspended particles by using a PTFE membrane as the filter medium. Stable filtration clarity can be obtained without using filter aids, and besides eliminating the use of filter aids, other merits include keeping running costs down.

Features

  • High-clarity filtration
    Continuously separates submicron particles without using filter aids. Applicable to a wide range of raw solution concentrations (10 to 10,000 mg/L), and offers stable clarity (0.4 mg/L or less) regardless of concentration fluctuations during operation.
    Washes and restores the filter medium in a short time, through instantaneous back-pressure washing with very little pause in operation (non-filtering time).
    Easy to operate, with pre-coating, washing and discharging operations that can all be simplified.
  • Concentration recovery of cakes
    Concentration of cakes by repeating filtration and backwash.
    Recovery of cakes at high concentration rates (100 to 3,001 times).
    Concentrates and recovers pure cakes without using a filter aid.
  • Improved separation/filtration process
    The <Sepaner filtration system> integrates conventional separation processes such as coagulation, settlement, and filtration, and offers drastic improvements in installation costs, installation space, maintenance, etc.
    Reduces both the amount of waste and running costs, since neither coagulants nor filter aids are used.
    The <Sepaner filtration system> integrates two-step filtration processes for thick solutions, such as centrifugation/high-clarity filtration, into a single step.

Model FDS Clarifying Filter

Technical Specifications

Model FDS45 FDS55 FDS65
Filtration area [m2] 2.4 3.6 4.8
Installation space [mm] 1,500×2,500 1,600×2,620 1,800×2,750
Volume of vessel [m3] 0.24 0.36 0.51
Operation weight [ton] 0.9 1.2 1.6
Inlet & Outlet Dia. [mm] 25 25 40
Required air volume
[When backwashing]
[0.2MPa×N L/min]
240 360 500
Model FDS75 FDS90 FDS105
Filtration area [m2] 7.2 10.8 15.6
Installation space [mm] 2,000×2,850 2,400×3,000 2,800×3,200
Volume of vessel [m3] 0.71 1.05 1.45
Operation weight [ton] 2.0 2.5 3.5
Inlet & Outlet Dia. [mm] 40 40 50
Required air volume
[When backwashing]
[0.2MPa×N L/min]
700 1,000 1,500
Model FDS120 FDS130 FDS140
Filtration area [m2] 19.8 24.0 28.2 / 35.25
Installation space [mm] 3,000×3,500 3,200×3,500 3,200×4,000
Volume of vessel [m3] 1.95 2.4 2.8 / 3.5
Operation weight [ton] 4.5 5.2 6.1 / 7.0
Inlet & Outlet Dia. [mm] 65 65 80
Required air volume
[When backwashing]
[0.2MPa×N L/min]
2,000 2,400 3,500
Model FDS160
Filtration area [m2] 42.75 / 51.3
Installation space [mm] 3,500×4,300
Volume of vessel [m3] 4.3 / 5.1
Operation weight [ton] 10 / 11
Inlet & Outlet Dia. [mm] 100
Required air volume
[When backwashing]
[0.2MPa×N L/min]
5,000

* Selection of filtration volume, the pump and motor are depend on the applications.

* Standard design pressure is 0.4MPa, and differential pressure is 0.05MPa.