Model FD Tubular backwash type micro-clarifying filter
This type of backwashable tubular filter is the most suitable for full automatic clarifying filtration. This system allows complete washing in a few minutes by applying reverse flow of filtrate kept in the top of the filter chamber.
The application ranges of micro-clarifying filtration has been extended to non precoat filtration by selecting filter cloth and clarity, and combinations of precoat equipment and/or dewatering devices.
Features
- Instant filtrate reverse flow mechanism makes high washing efficiency.
- Filter media and filter cloth are easily installed due to the simple tubular structure.
- This system allows simple operation and circulation circuit of
Precoat operation → Filtration → Washing.
Applications
- Plating solutions
- Coolant solutions
- Chemicals
- Saturated salt solution
- Rinse solutions
- Pretreatment process of galvanized coating
- Fluxing solutions
Technical Specifications
Model | FD45 | FD55 | FD65 |
---|---|---|---|
Filtration area [m2] | 2.4 | 3.6 | 4.8 |
Installation space [mm] | 1,500×2,500 | 1,600×2,620 | 1,800×2,750 |
Volume of vessel [m3] | 0.24 | 0.36 | 0.51 |
Operation weight [ton] | 0.9 | 1.2 | 1.6 |
Inlet & Outlet Dia. [mm] | 40 | 40 | 40 |
Required air volume [When backwashing] [0.19MPa×N L/min] |
480 | 720 | 1000 |
Model | FD75 | FD90 | FD105 |
---|---|---|---|
Filtration area [m2] | 7.2 | 10.8 | 15.6 |
Installation space [mm] | 2,000×2,850 | 2,400×3,000 | 2,800×3,200 |
Volume of vessel [m3] | 0.71 | 1.05 | 1.45 |
Operation weight [ton] | 2 | 2.5 | 3.5 |
Inlet & Outlet Dia. [mm] | 50 | 50 | 65 |
Required air volume [When backwashing] [0.19MPa×N L/min] |
1400 | 2000 | 3000 |
Model | FD120 | FD130 | FD140 |
---|---|---|---|
Filtration area [m2] | 19.8 | 24 | 28.2 / 35.25 |
Installation space [mm] | 3,000×3,500 | 3,200×3,500 | 3,200×4,000 |
Volume of vessel [m3] | 1.95 | 2.4 | 2.8 / 3.5 |
Operation weight [ton] | 4.5 | 5.2 | 6.1 / 7.0 |
Inlet & Outlet Dia. [mm] | 80 | 100 | 150 |
Required air volume [When backwashing] [0.19MPa×N L/min] |
4000 | 4800 | 7000 |
Model | FD160 |
---|---|
Filtration area [m2] | 42.75 / 51.3 |
Installation space [mm] | 3,500×4,300 |
Volume of vessel [m3] | 4.3 / 5.1 |
Operation weight [ton] | 10 / 11 |
Inlet & Outlet Dia. [mm] | 200 |
Required air volume [When backwashing] [0.19MPa×N L/min] |
10000 |
* Selection of filtration volume, the pump and motor are depend on the applications.
* Standard design pressure is 0.4MPa, and differential pressure is 0.15MPa.